Experimental study on performance of condenser of two different types used in window air conditioner
Madhu Jhariya1* , P.K.Jhinge and R.C. Gupta2
1 Jabalpur Engineering College, Jabalpur-482011, MP, India 2Department of Mechanical Engineering, Jabalpur Engineering College, Jabalpur-482011, MP, India
A B S T R A C T
This research paper presents the experimental performance of a window air conditioner with two different types of condensers, single channel and multi channel condenser. The air-conditioner is a 1 TR unit designed for R-22. The performance of the air-conditioner with R-410A is compared with the baseline performance with R-22.The performance parameters considered are cooling capacity, coefficient of performance, energy consumption, and compressor work done. Test results shows that for R-22 the COP of multi channel condenser is 6.6% efficient than the single channel condenser. The cooling capacity of multi channel condenser is 38.4 % higher than the single channel condenser.
Keywords
Window Air Conditioner; Refrigerant; R-410A; COP; and Cooling Capacity